Mechanical
1. Air Conditioning and Ventilation System
- Relevant Regulations
- Uniform Building By-Laws, 1984 / Sarawak Building Ordinance, 1994
- Certificate of Completion and Compliance / Certificate of Fitness for Occupation / Occupation Certificate / Occupation Permit
- Environmental Quality (Refrigerant Management) Regulations
- Applicable Standards
- ASHRAE Standards
- MS 1525 : Code of Practice on Energy Efficiency & Renewable Energy for Non Residential Buildings
- MS 1472 : Smoke Control in Protected Escape Routes using Pressurization
- MS 1780 : Smoke Control using Natural (Displacement) or Powered (Extracted) Ventilation
- MS 2586-7 : Smoke duct sections
- MS 2449 : Performance rating of water-chilling packages using the vapour compression cycle
- MS 2578-2 : Cooling tower
- Type of Systems and Local Applications
- Air-cooled Split Systems
- VRF Systems
- Package Units – Air-cooled & Water-cooled
- Centralized Chilled Water Systems
- District cooling systems
- Design Considerations
- Design Parameters – Temperatures, Air movement etc.
- Overall Thermal Transfer Value (OTTV)
- Roof Thermal Transfer Value (RTTV)
- Energy Efficiency & Building Energy Intensity
- Sustainability and Green Building Index
2. Fire Protection
- Relevant Regulations
- Uniform Building By-Laws, 1984 / Sarawak Building Ordinance, 1994
- Fire Services Act, 1988
- Fire Services (Designated Premises) Order 1998
- Fire Services (Fire Certificate) Regulations, 2001
- Certificate of Completion & Compliance / Certificate of Fitness for Occupation/ Occupation Certificate / Occupation Permit
- Applicable Standards
- MS 1489 : Hydrant Systems, Hose Reels and Foam Inlets
- MS 1539 : Portable Fire Extinguishers
- MS 1745 : Fire Alarm and Detection Systems
- MS 1910 : Automatic Sprinkler Systems
- MS 1590 : Carbon Dioxide Extinguishing Systems
- Environmental Quality (Halon Management) Regulations 1999
- Fire Safety Requirements
- Type of occupancy and purpose groups
- Fire safety systems for different purpose groups
- Limits of compartmentation in buildings
- Firefighting systems required for various types of buildings
- Design Considerations
- Portable fire extinguishers
- Hose reel systems
- Dry riser systems
- Wet riser systems
- Automatic sprinkler systems
- Gaseous extinguishing systems
- Fire alarm and detection systems
- Voice evacuation and firemen intercom systems
- Emergency generating systems
- Emergency lighting and exit signs
- Fire lifts
- Local Practices
- Design submission procedures to Jabatan Bomba dan Penyelamat Malaysia.
- Documents required for application for inspection
- Application of Forms C1, C2 and C3